BMW engine will not start at times at very low outside temperatures (-4°F/-20°C and colder); however, the battery state of charge is correct and the starter turns the engine over properly.This starting difficulty is most likely to occur after shutting the engine off briefly for 5 or 10 minutes, such as when refueling.
N20 engine:
1B5202 – Terminal 15N_1: No voltage
1B5302 – Terminal 15N_2: No voltage
1B5402 – Terminal 15N_3: No voltage
N52T engine:
1B5102 – Terminal 15N_3: line from CAS, electric: short circuit to earth
1B5501 – Terminal 15N: No voltage
1F0601 – Terminal 15N from CAS, switching delay: Switches too late
N55 engine:
1B5202 – Terminal 15N_1: No voltage
1B5302 – Terminal 15N_2: No voltage
1B5402 – Terminal 15N_3: No voltage
In addition, other engine electronic power supply-related faults could be stored for components such as VANOS solenoids, camshaft sensors, engine oil pressure sensor, engine oil pressure control valve, engine oil level sensor, etc.
CAUSE
At very low outside temperatures, low levels of moisture present inside the power distribution module (PDM) can freeze the internal micro-relay contacts.
CORRECTION
F25 and F26
Replace the PDM module and install the cover (if not already present) with the plastic rivet.
Important:
Follow the instructions in the attachment. This will help ensure that the power supply wiring does not contact the cover.
F15 and F16
Replace the PDM module and install the cover (if not already present) using the existing mounting screw.
Important:
The replacement PDM module part number listed below is only to be used in the case of a failure at very low ambient temperatures, as described above.
All other repairs requiring a PDM replacement must be done using P/N 12 63 7 591 534 and/or as specified in ETK