How to Add BMW F30 2012 FEM Spare Key with Auro OtoSys IM100/IM600

Note: Both IM100/IM600 has BMW FEM/BDC capability. IM600 is capable of BMW CAS4 and Mercedes-Benz key programming, while IM100 does not. If you are interested in IM600, please send email to us:sales@obd2tool.com

Main Steps:

Check key status

Backup EEPROM data

Learn Key

Procedure:

Step 1: Check key status

Disassemble FEM/BDC module

Connect with FEM module, IM100 and UP200 programmer

Select IMMO function->BMW->System selection->FEM/BDC immobilizer

2

3

Make sure the engine is off

4

Check Key Status

5

Put the tested key/working key into induction antenna

6

Put another keys into induction antenna one by one to check key status. New keys are not locked.

Step 2: Backup EEPROM

Back to BMW menu, select Smart Mode

detect current immobilizer system is FEM/BDC

Reading vehicle information and ecu information

Backing up coding files

Going to modify EEPROM data automatically:

  1. Please disassemble the EEPROM chip and connect the programmer
  2. The FEM module is chip M9S128 and the BDC module is chip M95256
  3. If you operate the EEPROM with clamp, you should turn off the +12V power first!

7

Backup EEPROM data automatiocally

Automatically modified EEPROM data successfully

The backup path is /mint/sdcard/scan/UserData/autobackup/

EEPROM chip operated successfully! Please install the chip back to the ECU module

Step 3: Learn Key

8

Notice:

The programming is about to start, make sure the supply voltage exceeds 13V and is stable.

1.Please make sure that the vehicle power is ok

2.Please make sute that the OBD diagnostic cable is correctly connected

  1. Please make sure that the power icon on the top right corner of the AURO OtoSys IM100diagnostic tool correctly displays the voltage.

9

Programming key in procedure

10

Going to restore EEPROM data automatically:

  1. Please disassemble the EEPROM chip and connect the programmer
  2. The FEM module is chip M9S128 and the BDC module is chip M95256
  3. If you operate the EEPROM with clamp, you should turn off the +12V power first!

Restoring EEPROM data automatically

EEPROM chip operated successfully. Install the chip back to ECU module

11

The restoration coding file is about to start

1.Please make sure that the vehicle power is ok

2.Please make sute that the OBD diagnostic cable is correctly connected

  1. Please make sure that the power icon on the top right corner of the diagnostic toolcorrectly displays the voltage.

Restore coding data files.

12

Note:

1.Before the key can be written and cleared, the password must be read out first.

2.Before the key can be written or cleared, the corresponding key position must be selected first.

 

Do you have a working key? Yes.

Insert working key into emergency start coil, select Read password

13

Read password, DME, ISN code success

14

Insert a new key into induction coil, select a key position and press Write Key

15

Key learning has 4 steps,

The first step of authenticating key information is in progress

The seconds steps if writing data into key is in progress

The third step of resetting ecu is in progress

The fourth step of verifying key information is in progress

16

Write key success.

Put the key close to start induction coil, press and hold the ingnition for 10s.

After key learning is completed, the key can be normally used.

17

You can program next key with AURO OtoSys IM100

Notice:

When the number of keys is greater than three, the newly added keys may have no remote control function due to the imitation of BMW system.